  1. Using the Compucom Speedmodem with SPITFIRE 3.0 BBS Software:
  2.  
  3. This is by no means a technical document on all the different ways to
  4. initialize your CompuCom Speedmodem for SPITFIRE, but a SIMPLE guide.
  5.  
  6. oo ..Be sure the Speedmodem ROM version is at least 2.51. Type ATI3...
  7. \/ ..from any communications program in TERMINAL mode for results...
  8.    ..EXAMPLE: (c) Copyright CompuCom 1990 V2.51
  9.  
  10. oo ..Refer to the init string below...
  11. \/
  12.  
  13. SPITFIRE /I19200 /C2 /M AT&F2 +F *H2%C0 S0=0S2=1&C1&D2V1Q0M0H0X1&W
  14.           |       |   | |___| |  |____| |________________________|
  15.           |       |   | |     F  |      |
  16.           |       |   | |     A  |      Recommended for Spitfire!
  17.           |       |   | |     X  |
  18.           |       |   | |     |  Depends on error mode wanted
  19.           |       |   | |     O  *H1 or *H2    (MNP-5)
  20.           |       |   | |     F  *H1 or *H2%C0 (MNP-4) -|Recommend
  21.           |       |   | |     F  *H1 or *H2\N0 (no MNP)-|either one
  22.           |       |   | |     |
  23.           |       |   | |     For COMBO only, do NOT use on CHAMP.
  24.           |       |   | |     NOT USED FOR Roms after 4/1/91
  25.           |       |   | A must for Speedmodem!
  26.           |       |   |
  27.           |       |   OVERRIDES Spitfire init string...
  28.           |       |
  29.           |       Selects com port...
  30.           |
  31.           Locks the port...
  32.  
  33.           
  34. oo ..Place it in the file SF.BAT that starts Spitfire...
  35. \/
  36.    ..(I.E.)
  37.  
  38. :LOOP
  39.    C:\
  40.    CD\SF
  41.    SPITFIRE /I19200 /C2 /M AT&F2+F*H2%C0S0=0S2=1&C1&D2V1Q0M0H0X1&W
  42.                                 ^^Not for roms after 4/1/91
  43. oo ..It is a good idea to change the actual string within Spitfire...
  44. \/
  45.  
  46. ╒═[ SPITFIRE NODE 1 MODEM CONFIGURATION ]═════════════════════════════╕
  47. │                                                                     │
  48. │ <S> Serial Port No................. : 2                             │
  49. │ <B> System Baud Rate............... : 19200                         │
  50. │ <I> Initialization String.......... :                               │
  51. │     AT&F2*H2%C0S0=0S2=1&C1&D2V1Q0M0X1H0&W                           │
  52. │ <M> Modem - Error Correction Type.. : Yes                           │
  53. │ <E> Error Correction Message....... : REL                           │
  54. │ <H> Hardware Data Flow Control..... : Yes                           │
  55. │ <A> Answer On What Ring............ : 1                             │
  56. │ <D> Display Result Messages........ : On                            │
  57. │ <C> Disconnect Delay............... : 3                             │
  58. │ <U> Use High Speed Async Routines.. : Yes/No oo ..Either way works..│
  59. │ <R> Baud Rate Requirement.......... : 0      \/                     │
  60. │                                                                     │
  61. │                   Enter Command or <Q>uit -                         │
  62. │                                                                     │
  63. ╘═════════════════════════════════════════════════════════════════════╛
  64.  
  65. oo ..*H2%C0 can be substituted with other variations...
  66. \/ ..as recommended in the Speedmodem manual...
  67.  
  68. oo ..If using the COMBO, add +F to the Initialization string...
  69. \/ ..turns fax off on the COMBO, returns ERROR on the CHAMP...
  70.      NOTE: +F NOT USED for roms after 4/1/91
  71.  
  72. Dialing out:
  73.  
  74. oo ..RTS-CTS ON, ALL BAUD at 19200, AUTO BAUD DETECT OFF...
  75. \/
  76.    ..When using a long distance carrier with the Speedmodem...
  77.    ..call your LD customer service and ask if a "carrier code"...
  78.    ..is needed for proper "bandwidth" on "asynchronous" connections...
  79.  
  80. oo ..An example where this code is needed is the US Sprint...
  81. \/ ..FIBER OPTIC NETWORK, to access a ""full-bandwidth" line...
  82.    ..the code 10333 is needed, that is dial 10333-1-800-000-0000...
  83.    ..this ensures that the FULL bandwidth is available to you...
  84.    ..otherwise, a sudden "No carrier" can result...
  85.  
  86. This by no means covers all the ways to use SPITFIRE with a Compucom 
  87. Speedmodem.  But it should help you initially (pun?).  If all else 
  88. fails, don't forget to read the doc's!